Before operating the Howo water tanker truck pump, ensure the liquid level within the pump surpasses the pump shaft. Achieve this by installing an upwardly angled elbow at the pump inlet, followed by a horizontal pipe and a quick connector. Position the centerline of the quick connector 300 mm above the pump shaft’s centerline. Design the inlet piping system to eliminate air leaks, and keep the suction head of the suction pipe fully submerged to prevent air from entering the water line. When connecting the outlet pipe to the pump outlet, extend the straight pipe at least 200 mm before attaching the elbow.
The Howo water tanker truck pump is capable of performing both water absorption and pressurized drainage functions. This self-priming pump can efficiently draw water from a pond into the tank or directly connect to a city street fire hydrant to extract water for sprinkling purposes.